Diagnostic LEDs on the Origin2000/Rackmounted Onyx2 Compute Module Midplane.

There are 18 LEDs on the midplane of the Origin2000 or rackmounted Onyx2 compute module (Deskside Onyx2's have a different configuration). The LEDs can be used to diagnose the status of XBOW to device links, and communication errors between processor nodeboards, the XBOW and XIO slots. Sixteen of the eighteen of the LEDs are green, when illuminated those indicate a successful link to the indicated device. The remaining two LEDs are amber. If either of the amber LED are illuminated there is an XBOW communications link error in the respective XBOW.

The system must complete the primary initialization (possibly as long as several minutes) before the LEDs can be read.

The LEDs are separated into two groups:

Bank 0 - Indicates the status and devices connected to XBOW 0:

   *Processor nodeboards 1 & 3 - marked as N1 and N3 - green LEDs indicate a successful link.
   *XIO slots 1 through 6 - marked as W1 through W6 - green LEDs indicate a successful link. 
   *XBOW 0 link error status - marked as X0 Link Error - an amber LED indicates a communication error between the nodeboard, XBOW and XIO slots.
Bank 0 is located on the midplane behind the PCI cardcage or cardcage blanking plate.

Note that the XBOW 0 Link Error LED is located separately from the other XBOW 0 LEDs; it is represented by the upper red rectangle in the following image:

XBOW 0 LEDs are located on the midplane behind the PCI cardcage or cardcage blanking plate (the cardcage slot is labeled as IO2 on the chassis)
A detail of the position of the XBOW 0 Link Error LED:
Location of XBOW 0 Link Error LED (marked X0 Link Error)
And a detail of the LEDs for XIO slots 1 through 6 and nodeboards 1 & 3:
Location of the LEDs for nodeboards 1 & 3 (marked N1 and N3) and XIO slots 1 through 6 (marked W1 - W6)

Bank 1 - Indicates the status and devices connected to XBOW 1:

   *Processor nodeboards 2 & 4 - marked as N2 and N4 - green LEDs indicate a successful link.
   *XIO slots 6 through 12 - marked as W7 through W12 - green LEDs indicate a successful link.
   *XBOW 1 link error status - marked as X1 Link Error - an amber LED indicates a communication error between the nodeboard, XBOW and XIO slots.
Bank 1 is located on the midplane behind the IO6 or Io6G:
XBOW 1 LEDs are located on the midplane behind the IO6 or IO6G
A detail of the XBOW 1 LEDs:
Location of the LEDs for nodeboards 2 & 4 (marked N2 and N4), XIO slots 6 through 12 (marked W6 - W12) and the XBOW 1 Link Error LED (marked X1 Link Error)